Technical datas Passvie House disk
Key figures PHPP: PHPP 1998 - Passive House Planning Package (first) PHPP 2014 - Passive House Planning Package (for certification) PHI Certification-ID: 8941 |
|
Treated floor area: 140 m2 |
Nine years evaluation with top results |
Annual heat demand: 13.0 kWh/m2a Primary energy demand: 114.1 kWh/m2a
Annual heat consumption: 11.3 kWh/m2a |
|
|
|
Key figures national standard: OIB Richtlinie 6 (Stand 1998) - Oberösterreich - Energieausweis |
|
Gross floor area: 179 m2 |
|
Annual heat demand: 10 kWh/(m2a) |
|
|
|
Bauteil Aufbauten: | |
Roof construction: U-value 0.08 W/m²K extensive greening |
|
Exterior wall: U-value 0.10 W/m²K 2.5 cm gypsum plasterboard, 2-layered
|
|
Floor slab : U-value 0.12 W/m²K 3.0 cm OSB sealed |
|
Window: Uw-value 0.87 W/m²K Window frame Uf-value 0.75 W/m²K wooden windows with 4.0 cm highly compacted cork core frame Glazing Climatop Solar Ug-value 0.70 W/m²K Window frames fully superinsulated
|
|
House technic: | |
Type of ventilation system: Compact unit with exhaust air heat pump Controlled living space ventilation with heat recovery from exhaust air by compact unit including cross flow heat exchanger and micro heat pump, intake air pre-heating provided by supplementary heating register The compact aggregate is certified by the Passive House Institute Because of it's space requirements of only 0.75 m², including a 212 liter hot water boiler, the compact ventilation system could be placed on the toilet. All the ventilation pipes are "Spiro Wickelfalzrohre", which are viewable below the wooden beam ceiling. The cold incoming and outgoing air pipes are insulated with 10 cm aluminium foil-claid mineral wool. |
|
Heating system: 100 % green electricity for power demand. Reserve heating 1 emergency 2 kW bioethanol-fired stove of max. 2 kW, free-standing in the living room, without chimney. |
|
Hot water: The needed hot water is produced from the outgoing air by the micro heat pump of the compact aggregate with cross-flow heat exchanger and saved in the 212 liter hot water boiler. |
|
Electricity saving concept: All electrict devices were bought according their energy efficiency class. Stromerzeugung: 100 % green electricity consumption |